EasyManuals Logo
Home>Baur>Test Equipment>Syscompact 2000

Baur Syscompact 2000 User Manual

Baur Syscompact 2000
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
29
7 Accurate fault location (pin pointing)
Danger! High-voltage
When using surge mode:
Cordon off syscompact at a distance of 1.5 m
Persons must stand only outside the barrier
Accurate fault location is made with UL 30, BM 30 and SSG according to the acoustic
location method.
Switch HV on, SSG to permanent impulse, increase voltage up to a clearly visible breakdown
sound is audible.
Both pull switches at the SA 32 have to be on position SSG (both pull switches pressed). If
one of the two pull switches remains in pulled position, no flash-over noise is audible. In case
of not pushed in rods the incorporated resistors could be thermal destroyed.
Please see Locator Set user manual!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baur Syscompact 2000 and is the answer not in the manual?

Baur Syscompact 2000 Specifications