5.3.7 Encryption and Security Settings page
Figure5.6: Encryption and Security Settings Page
Encryption Enable
Default: No
Selections: Yes, No
Yes: All UDP communication (RPS and event reports) through the network module is
encrypted. AES encryption must also be set at the central station receiver and the PC running
RPS.
No: All communication through the network module is unencrypted.
Use this option to enable or disable Advanced Encryption Standard (AES) encryption on the
module.
For B9512G/B8512G, B6512/B5512/B4512/B3512, and GV4 v2.xx control panels with Panel
Programming Enable set to Yes, the module does not enable encryption regardless of the
setting.
AES Key Size
Default: 128
Selections: 128, 192, 256
Use this option to select the AES key size. The AES key size must match the key size used in
RPS and the receiver.
AES Key String
Default: The default varies by key size.