1070 072 449-102 (01.12) GB
RROFIBUS-DP4-2
4.2 Setting of Bus Address
Each node at the PROFIBUS-DP must receive its own bus address.
The bus address of the RM2-DP12 module is set by means of the S1 DIP
switch.
Þ
ÞÞ
Þ The set bus address will only be scanned during run-up, i.e. when
the supply voltage is applied to the X10 connection.
Switch 87654321
Significance 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Value 1286432168421
Fig. 5 DIP Switch S1
4.3 Baud Rate
The module adapts itself automatically to the PROFIBUS-DP's baud rate
(9600 Baud - 12 Mbaud).