5-59
Confidential
1.3.31 Reset counters for consumable parts (function code: 88)
<Function>
This function is performed to reset the counter for each consumable part in the main PCB
after that has been replaced.
<Operating Procedure>
(1) Press the [8] key twice in the initial state of maintenance mode. "Reset-Laser Unit" is
displayed on the LCD.
(2) Press the [â–²] or [â–¼] key to display the part with the counter to be reset on the LCD, and
press the [Mono Start] key.
(3) "*******OK?" is displayed on the LCD. Press the [Mono Start] key to reset the counter for
the selected part and return the display to the procedure (2). (******* represents the
name of the selected part)
(4) Press the [X] key, and the machine returns to the initial state of maintenance mode.
Selectable parts are shown in the table below.
LCD Part name Counter to be reset
Reset-Laser Unit Laser unit Printed pages counter
Reset-Fuser Unit Fuser unit Printed pages counter
Reset-PF Kit T1 PF kit 1 Printed pages counter
Reset-PF Kit T2 PF kit 2 Printed pages counter
Reset-PF Kit T3 PF kit 3 Printed pages counter
Reset-PF Kit T4 PF kit 4 Printed pages counter
Reset-PF Kit T5 PF kit 5 Printed pages counter
Reset-PF Kit MP PF kit MP Printed pages counter
Reset-LVPS Low-voltage power supply
PCB ASSY
Irregular power supply detection counter