Page 32
ENABLE ADS?
This function allows the operator to choose whether
or not to display the advertising message that was en-
tered into the brewer with an AD CARD. This message
will be displayed when the brewer is not in use.
ENABLE ADS?
NO DONE YES
Procedure to Enable/Disable Ads:
1. Press and hold upper right hidden switch until the
display reads SET NEW RECIPES. Release switch.
Press and release upper right hidden switch until
the display reads ENABLE ADS. The YES or NO
will be fl ashing to indicate the current selection.
2. Press and release the NO pad to disable this func-
tion (no ads will be displayed on the screen), or;
3. Press and release the YES pad to enable this func-
tion (ads will be displayed on screen).
4. When fi nished, press and release DONE to save
the new setting, exit the ENABLE ADS function and
advance to the next function screen, SET TEMP.
Another alternative is to press and release either
of the pads located on the front switch panel
to exit the ENABLE ADS function and return to the
MAIN SCREEN.
SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)
This function allows the operator to set the brew
water temperature in the tank. It also sets the hot
water faucet dispense temperature.
P2301
PROGRAMMING FUNCTIONS - (cont.)
P2302
Procedure to set brew temperature:
1. Press and hold upper right hidden switch until the
display reads SET NEW RECIPES. Release switch.
Press and release upper right hidden switch until
the display reads SET TEMP.
P2303
2. To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
3. When fi nished, press and release DONE to save
the new setting, exit the SET TEMP function and
advance to the next function screen, SET READY.
Another alternative is to press and release either
of the pads located on the front switch panel
to exit the SET TEMP function and return to the
MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
SET TEMP: XXX°
(-) DONE (+)
SET READY: XXX°
(-) DONE (+)
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The
range can be from 185˚F (85˚C) to within 2˚F of the SET
TEMP. The water must be at the SET READY tempera-
ture or higher for the display to indicate READY TO
BREW. If brew lockout is enabled, the brewing process
will not start below this READY temperature.
NOTE: The upper limit is the water temperature control
setting minus 2˚ F (1.7˚C)
"REWWATERTEMPERATUREISFACTORYSETATo&o#
!REASOFHIGHALTITUDEWILLREQUIRELOWERINGTHISTEMPERA
TURETOPREVENTBOILING4HISCHARTSHOULDBEUSEDASA
GUIDEWHENREADJUSTINGTHEBREWWATERTEMPERATURE
!LTITUDE
&EET
"OILINGPOINT
OFWATER
o&o#
2ECOMMENDED
WATERTEMPERATURE
o&o#
29877.2 121504