FACTORY DEFAULTS
This function allows the operator to erase all of the
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
EXIT
EXIT
REPLACE
WILL REPLACE ALL
BREW SETTINGS
ARE YOU SURE?
NO YES
FACTORY DEFAULTS
NO YES
Procedure to set factory defaults:
1. Press and hold upper right hidden switch until SET
NEW RECIPES appears. Release switch. Press and
release upper right hidden switch until the display
reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN
SCREEN. Press YES to replace the defaults. This
advances to WILL REPLACE ALL BREWING SET-
TINGS. This screen will alternate with ARE YOU
SURE?.
3. Pressing NO in the confi rmation screen will revert
to MAIN SCREEN, without resetting the brewing
setups to the defaults. Press YES to load the de-
faults. This will then revert to the MAIN SCREEN,
and the factory default values will replace all
previously entered values. It will NOT reset the
summation Brew counter.
P2312
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
BREW LOCKOUT YES
ENABLE ADS NO
BREW TEMPERATURE 200˚F (93˚C)
READY TEMPERATURE 195˚F (91˚C)
SPRAY (OZ/MINUTE) 39.2
BYPASS (OZ/MINUTE) 24.1
FUNNEL LOCKOUT YES
SERVER LOCKOUT YES