Page 35
PROGRAMMING FUNCTIONS -(cont.)
CALIBRATE FLOW (cont.)
Procedures to calibrate the bypass fl ow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, below
the funnel on the brewer to be calibrated.
2. Press and hold upper right hidden switch until the
display reads SET NEW RECIPES. Release switch.
Press and release upper right hidden switch until
the display reads CALIBRATE FLOW?.
3. Press and release YES to advance to the SPRAY
HEAD CAL? function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release NO to advance to the BYPASS
CALIBRATION screen.
5. Press and release the YES pad. The display should
read CONTAINER READY? If the container is
under the funnel, press YES. The display should
read CALIBRATE BYPASS .. PRESS BREW TO
START.
6. Press and release the pad on the side to be
calibrated. The display should read CALIBRATE
BYPASS .. 60 SEC TO FINISH. The 60 second timer
on the display will count down to zero. When the
counter reaches zero, the display will change to
LEFT or RIGHT OZ., along with a number signify-
ing ounces per minute.
7. Measure the amount of water in the container, and
using (-) or (+), adjust the amount on the display
to match the amount in the container. Then press
DONE.
8. The display should now read NEW L or R BYPS
FLOW, along with the correct fl ow rate of the by-
pass in ounces per minute. After about 5 seconds,
the display will return to the CALIBRATE FLOW
screen.
9. To exit the CALIBRATE FLOW function, press and
release NO to advance to the next function screen,
or press and release the pad located on the
front switch panel to exit the CALIBRATE FLOW
function and return to the MAIN SCREEN.
10. Repeat steps 1 - 9 when calibrating the other
side.
P2609
LEFT OZ XX.X
(-) DONE (+)
NEW L BYPS FLOW
XX.X OZ/M
L or R
Left or Right
EXIT TO THE
NEXT FUNCTION
SCREEN
COUNTS DOWN
TO ZERO
BREW PRESSED
AFTER 1 MINUTE
CALIBRATE FLOW?
NO YES
CONTAINER RDY?
NO YES
CALIBRATE BYPASS
PRESS BREW START
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS CAL?
NO YES
SPRAYHEAD CAL?
NO YES
29877.2 121504

Other manuals for Bunn DUAL SH DBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn DUAL SH DBC and is the answer not in the manual?

Bunn DUAL SH DBC Specifications

General IconGeneral
BrandBunn
ModelDUAL SH DBC
CategoryCoffee Maker
LanguageEnglish

Related product manuals