DC10 E, DC20 E
SERVICE MODE / ADJUSTMENT
23
5-3-1 VCM Adjustment
SPEC. Automatic adjustment
Procedure)
(1) Referring to the table shown below, carry out VCM adjustment.
Fig. 17
ST
STEP PROCEDURE Microcomputer operation
Preparation for VCM adjustment CS Function MD ADDR DT
1 1) Make the setting shown at right. 2 08 ST 3119 00
2) Perform storing.
↑↑
RD
↑↑
It will take a period of ten seconds
(press the PAUSE button.) OK with ST : 19
2 1) Make the setting shown at right. 2 08 ST 311A --
2) Perform storing.
↑↑
RD
↑
AA Correction value calculation.
(press the PAUSE button.) OK with ST : AA, NG with ST : FE
MONITOR