– 19 –
6-2. Outdoor Unit (38NYV025M, 38NYV025M-A)
No. Parts name Model name Rating
1 SC coil L01 GET-04051 0.6mH, 15A
(Noise filter) L03
GET-04052 2.0mH,10A
Primary side DC280V, Secondary2 DC-DC transformer
SWT-72
side 7.0 V x 1, 12 V x 1, 17V x 2
3 Reactor CH-57-Z-T L=19mH, 10A
4 Outside fan motor
20W
5
G5NB-1A Coil DC12V Contact AC250V-1.5A
6
Outside air temp.
(Inverter attached) 10kΩ (25°C)
sensor (TO sensor)
7
Heat exchanger temp.
(Inverter attached) 10kΩ (25°C)
sensor (TE sensor)
9
JX0-6B
20A, AC250V
Terminal block (6P)
10
11
Fuse
For protection of switching power source 3.15A, AC250V
For protection of inverter input overcurrent 25A, AC250V
12
Electrolytic capacitor LLQ2G501KHUBTF 500µF, DC 400 V x 3 pieces
13
Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
Rectifier
14
Fan control relay
D15XB60-4001 15A, 600V
16 4-way valve coil
AC220-240V
17
Running capacitor
DS451155NPQB AC450V, 1.5µF
(for fan motor)
IGBT GT15J321 15A, 600
Compressor DA89X1C-23FZ 3-phases 4-poles 750W
15
8
Dischenge temp.
(Inverter attached) 62kΩ (20°C)
sensor (TD sensor)
SKF-240-20B-1
No. Parts name Type Specifications
1
Fan motor
AFS-220-20-4AR
AC Motor with 145°C thermo fuse
2 Thermo. sensor (TA-sensor)
3 Micro power module (T101)
4 Micro controller unit (IC81)
6 Line filter (L01) SS11V-R06270 27 mH, AC 0.6A
7 Diode (D01,D02,D03 and D04) S5688J
8 Capacitor (C03) 47 F, 400 V
9 Fuse (F01) FJL 250 V 3.15A 3.15A, 250 V
11 Varistor (R21) TNR10V471K-T8 470V
12 Louver motor 24BYJ48 DC 12V
EKMH401VSN470MP20S
µPD780076GK-703-9ET-A
5 Heat exchanger sensor (TC-sensor) 10 kΩ at 25°C
FILE NO. SVM-07009
6-1. Indoor Unit
6. SPECIFICATION OF ELECTRICAL PARTS
DC Motor Over Heat protection circuit
10 kΩ at 25°C
µ
10 Regulator IC (IC12) S7805PIC 5VDC, 0.5A
µRM1260V