64
Operation
Measure
Item by symptoms
Check item
Conceivable principle
cause
Parts
(D01, D04,
C03, T101
and IC12)
are defective.
Be sure to disconnect the motor connector CN10 after shut off the power supply, or it will be a cause of
damage of the motor.
(1) Power is not turned on (Does not operate entirely)
3
FILE NO. SVM-07009
11-5. Judgement of Trouble by Every Symptom
11-5-1. Indoor unit (Including remote controller)
Turn off power
supply once, and 5
second later, turn it
on again.
Is OPERATION
lamp blinking?
NO
YES
NO
NO
YES
YES
Is it possible to
turn on power
supply by
pressing
[ ] button
on remote
control?
Does
transmission
mark on
remote control
flash normally,
and is its signal
transmitted
properly?
Remote control is
defective.
Refer to (5)
Remote Control.
"
Is fuse (F01)
of indoor control
board blown?
Is voltage
(DC 12V or 5V)
indicated on
rear of indoor
control board
normal?
Microcomputer
is defective.
Replace main
P.C. board.
Refer to
<Primary check>
or this problem
is one step short
of power P.C.
Is the voltage
across
C03 measured
DC 310V~340V?
YES
YES
NO
NO
NO
NO
YES
Does
fan motor
connector
between 1
and
short-circuit?
Unit operates
normally.
board block.
Are DC 5V,
DC 12V
supplied
to main
P.C. board?
Turn off breaker
once and turn it
on again after
removing motor.
Regulator IC
(IC12) or T101
are defective
Replace motor
.
NO
NO
YES
YES YES
Are DC 5V,
or DC 12V
supplied
to main
P.C. board?
"Troubleshooting for

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38NYV025M-A and is the answer not in the manual?

Carrier 38NYV025M-A Specifications

General IconGeneral
BrandCarrier
Model38NYV025M-A
CategoryAir Conditioner
LanguageEnglish

Related product manuals