Figure 62: Cisco ASR 1002 Router +24 VDC Power Supply Lead Wire Inserted into the Terminal Block
Copper wire2Lead wire insulation1
Step 8 Make certain no copper wire is visible as shown in the following figure which shows the lead wire fully inserted.
Figure 63: Cisco ASR 1002 Router +24 VDC Power Supply Lead Wire Fully Inserted
Fully-inserted lead wire1
Step 9 After the lead wire is fully inserted, hold the lead wire in place by pressing inward while you remove the screwdriver
to release the spring to tension down on the installed lead wire, then perform these steps:
a) Hold the lead wire in place while you are removing the screwdriver.
b) Once the screwdriver is completely removed, gently pull on the lead wire to make certain that the lead wire is
securely installed.
The following figure shows a lead wire fully inserted and the screwdriver removed while you gently pull on the
lead to make certain it is secured in the terminal block.
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
95
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Replacing the +24 VDC Power Supply in Cisco ASR 1002 Router

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g