1.3 Versions - Options
Main components:
A Electronic filters
B Outdoor air exchanger
C Hot gas re-heating coil with capacity modulation
D Capacity modulating compressors
E Variable air flow fan on supply air
F Variable air flow fan on exhaust air
G Exhaust air exchanger
1.4 Example referred on Size 2
A
B
C
E
F
G
D
i
Matriculation plate
The matriculation plate is found on the unit and indicates all
machine features.
The matriculation plate must never be removed.
The matriculation plate shows the indications foreseen by the
standards, in particular:
the type of machine
range → CSNX-XHE
size → 82 or 102 or ….
the serial number
12 characters → Axxxxxxxxxxx
the year of manufacture
the wiring diagram number
electrical data
manufacturer logo and address
Serial number
Unambiguously identifies each machine.
Enables identifying the specific spare parts for the machine.
Intervention requests
From the matriculation plate, take note of the characteristic
data on the table so they are easily available if required.
For request of intervention, always give the following data.
Range
Size
Serial number
Year of manufacture
Wiring diagram
1.2 Machine identification
1 - GENERALITY
VERSIONS
RTA Active thermodynamic recovery standard (std)
REFRIGERANT CIRCUIT
CCSTD Standard exchanger on exhaust air std
CESTD Standard exchanger on outdoor air std
EVE Electronic expansion valves std
CPHGM Hot gas re-heating coil with capacity modulation
std
AIR SIDE FEATURES
PCOSME Air flow constant in delivery and expulsion std
PVARC Variable air flow on supply and exhaust with CO2
probe
PVARCV Variable air flow on supply and exhaust with
CO2+VOC probe
FG4EE G4 class air filters on outdoor and exhaust air std
PSTAF Filters dirty differential pressure switch on extract
and delivery std
MHSEX Immersed electrodes steam humidifying module
MCHSX Steam-powered humidifying module
FEL Electronic filters std
ELECTRIC CIRCUIT
CRC Remote control with user interface std
NCRC Remote control with user interface: not required
MOB Serial port RS485 with MODBUS protocol
LON Serial port RS485 with LONWORKS protocol
BAC Serial port RS485 with BACnet protocol
CTU Temperature and humidity control std
RE Electric heaters std
DESM Smoke detector
PM Phase monitor std
INSTALLATION
II Indoor installation
IO Outdoor installation std
AMRX Rubber antivibration mounts