Location Requirements
The standard KNIGHT2 Model 409D can be mounted on any location that is 50” x 13”. The
surface should be flat or have only a slight crown. For a recessed installation allow for a
minimum of 60” x 20”. Consult with factory before construction of recessed installation.
Verify all dimensions before installation to ensure proper operation of light will not infringe
on other installed components. For all other installations refer to the dimensional drawing
included in the back of this guide that represents your particular model of light. The
drawings reflect the dimensions of the “working envelope” of a typical light tower. Make
certain sufficient clearances are incorporated in your installation to allow for variations
(vehicle body flex, environmental conditions, future servicing needs, etc.) If your light is not
represented, call the factory prior to beginning any construction of a recessed installation.
Four mounting bolt holes are required. Additional holes may be drilled in the frame ends if
necessary to clear obstructions.
Access holes for the power cord cabling should be in close proximity to the light. Installing
the cords with a sweeping 90 or 180 bend will provide better results.
The control box holster should be mounted in an area shielded from the weather. Allow a
minimum of 10” clearance above the control box holster mounting location for easy access
to the controller.