KNIGHT2
24
Technical Specifications – Standard DC Models (409D-H4)
Dimensions (with strobe and ½” mounting spacers) May vary by model:
Height(Depth)
Length
Width
Retracted
12
51
13
Extended
88
54
13
Recessed installation
14
60
20
Minimum
Weight:
190 pounds
Wiring:
Main Power VDC
2/2 SO cord
50’ provided
Control wiring
22/20 PVC Jacketed
50’ provided
Relay protection:
Lights
Cole-Hersey
3055
80 amps
Other electrical
Cole-Hersey
3055
40 amp
Current Draw / Power Requirements:
Average
Generator Requirement
2 x 60 Watt LED
12 VDC/55 amps
1 kW minimum
2 x 270 Watt LED
Lift actuators and rotation motor will cause higher current draw during use.
Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):
Lower stage
1:3 (90 seconds maximum per 5 minute)
Upper stage
1:3 (90 seconds maximum per 5 minute)
Rotation
5-6 Revolutions
Motor Speed:
Lower stage
1.0 inches per minute
12 seconds to full extension
Upper stage
0.5 inches per minute
12 seconds to full extension
Rotation
2.75 RPM at lamp tree
Operation:
Angle of vehicle
15˚ maximum incline
Wind load:
Design maximum
60 mph
Maximum tested
55 mph

Other manuals for Command Light KNIGHT 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Command Light KNIGHT 2 and is the answer not in the manual?

Command Light KNIGHT 2 Specifications

General IconGeneral
BrandCommand Light
ModelKNIGHT 2
CategoryLighting Equipment
LanguageEnglish

Related product manuals