USER GUIDE
17
Wire the 10 Awg blue/white and green wires to the middle pole strip in the relaybox. Also
wire the smaller cable into the middle pole strip in the relaybox.
Order:
1. 10 Awg Blue/White
2. 10 Awg Green
3. 16 Awg Green/Black
4. 16 Awg Green/White
5. 16 Awg Red/White
6. 16 Awg Brown
7. 16 Awg Blue/White
8. 18 Awg Brown/White
9. 18 Awg Purple
10. 18 Awg White/Black
11. 18 Awg Orange
12. 18 Awg Yellow/Black
13. 18 Awg Black
14. 16 Awg Green
Wire the small gray 22-20 control cable to the 20 pole strip color for color.
Crimp the provided 2 Awg / ¼” hole connectors on the black and red 2
Awg cables, red goes to the open “BAT” stud on the breaker and black
goes to the ¼” ground stud with the lamp ground wires.
Make sure all wires are tied back so they will not be crushed when the relaybox lid is put on.