35
For AKZ9-OP-Y
R1/8
(φ4.5)
Lead wire
27.5
80
SXH-001T-0.6
(φ5)
XHP-3 (Blue)
Optional Parts
Returned oil temperature control
When the following optional parts are mounted to the oil piping (return oil piping) of the main machine, the Oil Cooling Unit can
perform control by detecting the returned oil temperature.
Substitute the blue connector (XHP-3) of the above part for the blue connector [CN11] of the outlet oil temperature thermistor in
the electrical equipment box. (See “Outline of electrical equipment box” on page .)
See page .
Optional parts
Mounting procedure
Type
Lead wire
length
L (m)
Name Dimensions
Application
(Installed by user)
Compatible model
AKZ9–OP–Y10
AKZ9–OP–Y5
For returned oil
temperature control
(Mounted to main
machine oil piping)
AKZ9 series
Oil temperature
control thermistor
Oil Cooling Unit
Main machine
(10 m)
(5 m)
Rc 1/8 Screw seat
Oil piping
Connection to control board connector [CN11] of Oil Cooling Unit
Substitution for outlet oil temperature thermistor,
Operation in outlet oil temperature control mode No. 1, 5 or 6.
19
Characteristics of thermistor: Resistance R25 (resistance at 25˚C) = 20 k, Tolerance: ±3% (Temperature equivalent: ±0.4˚C)
10
Optional Parts
Optional
Functions
PIM00318A_EN.fm Page 35 Tuesday, October 26, 2010 12:37 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin AKZ439 and is the answer not in the manual?

Daikin AKZ439 Specifications

General IconGeneral
BrandDaikin
ModelAKZ439
CategoryAir Conditioner
LanguageEnglish

Related product manuals