11 | Commissioning
Installer reference guide
48
CTXM15+FTXM20~42+ATXM20~35R2/5V1B + FTXM50~71R2V1B +
ATXM50R2V1B
Daikin room air conditioner
4P518023-8G – 2020.06
11.3 To perform a test run
Prerequisite: Power supply MUST be in the specified range.
Prerequisite: Test run may be performed in cooling or heating mode.
Prerequisite: Test run should be performed in accordance with the operation
manual of the indoor unit to make sure that all functions and parts are working
properly.
1 In cooling mode, select the lowest programmable temperature. In heating
mode, select the highest programmable temperature. Test run can be
disabled if necessary.
2 When the test run is finished, set the temperature to a normal level. In cooling
mode: 26~28°C, in heating mode: 20~24°C.
3 The system stops operating 3minutes after the unit is turned OFF.
11.3.1 To perform a test run using the user interface
1 Press to switch the system on.
2 Press and simultaneously.
3 Press , select and press .
Result: Test run operation will stop automatically after about 30minutes.
4 To stop operation sooner, press .

Table of Contents

Other manuals for Daikin CTXM15R2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin CTXM15R2V1B and is the answer not in the manual?

Daikin CTXM15R2V1B Specifications

General IconGeneral
BrandDaikin
ModelCTXM15R2V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals