1-20
1.5.4 Ventilator Volume Detection
(FA Sensor)
Sometimes FA (Fresh Air) is taken in with the
ventilator opened in the chilled mode. The FA
volume can be displayed on the LCD screen or
recorded as log with the FA sensor. When the
ventilator is opened in the frozen mode, alarm
E807 is displayed.
The wire reel mechanism and position meter
are installed inside of the FA sensor. The wire is
connected to the ventilator outlet cover so that
the movement of the cover opening and closing is
converted into the variation of voltage to send to
the controller.
Ventilation cover
FA sensor CPU board
X8A
Either "Ventilator with insect screen" or "Ventilator
without insect screen" is set for the unit installed with
FA sensor at factory referring to 12 Configuration
Set in paragraph 2.3.
Setting of ventilation volume (FA volume)
Conduct the setting of ventilation volume after the
completion of the FA sensor calibration. FA sensor
characteristic differs between the ventilator opening
and closing. To display accurate FA volume, make
sure to follow the procedure of manual. Refer to
18 FA sensor calibration in paragraph 4.1.
Event log recording
FA volume (m3/h) is recorded as event log at the
following timings.
1. At FA setting, at FA change
2. 0:00 am (Once a day)
3. When the unit starts to run
4.
When the controller is waked up by battery
mode
1.5.5 Remote Monitoring Receptacle
Able to install receptacle for remote monitoring on
front of the unit.
In case of connect remote monitoring cable, below
operation conditions are transferred to main board.
1. Compressor running
2. Defrost
3. In-range
RM receptacle
A : Earth
D
C
A
B
B : Compressor
C : Defrost
D : In range
01章LX10F11B3TR16-02En.indd1-2001章LX10F11B3TR16-02En.indd1-20 2016/02/029:09:382016/02/029:09:38
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LX10F11B3 and is the answer not in the manual?

Daikin LX10F11B3 Specifications

General IconGeneral
BrandDaikin
ModelLX10F11B3
CategoryInverter
LanguageEnglish

Related product manuals