2-2
2.1 Operation Panel
ALARM LED (Red)
ALARM LED blinks in case of F alarms or E807
and E304.
IN RANGE LED (Green)
Lights when the control temperature is in range.
IN RANGE LED
OFF
IN RANGE LED
OFF
SP
SP+1
SP-2
SP+2
SP-1
SP
IN RANGE LED
ON
DEFROST LED (orange)
Lights when defrosting control is being carried out.
DEHUMID LED (yellow)
Lights when dehumidifying is set to ON.
Function of operation key
UNIT
ON/OFF
To start or to stop the unit operation.
If the power supply is cut off while the
unit is on, and the power supply is then
turned on again, the unit automatically
starts the operation without pressing
this key again.
UP DOWN
Scroll up or down to select an item
• Determine the setting item
LEFTRIGHT
Scroll right or left to select an item
Move to next or previous screen
MENU
To move to Battery Mode display
when no power is supplied
To move to Initialize Menu display
after unit ON/OFF key "ON"
To move to Menu display while
the unit is in operation
ENTER
To determine the setting contents
ESC
Returns from the display contents
to the previous screen.
MANUAL
DEFROST
To carry out manual defrost
operation
FULL COOL
COOLING OFF
MODULATION
HEATING
HEATING OFF
DEFROST
EMERGENCY STOP
EMERGENCY SHUTDOWN
*2 Supply air Temp.
Control humidity
Set Point temperature
Defrost interval
Humidity setting
Setting mode
Operation condition
MENU
RIGHT
UP
LEFT
DOWN
ESC
ENTER
Reserve
MANUAL
DEFROST
LP: 20kPa
FULL COOL
DEF-INT 12HR
SET-HU 70%RH
SET-MODE
DEHUMID
USDA
ASC
ACT
G-Set
*1 Return air Temp.
FROZEN
SUPPLY -18.6
HP1200kPa
SET POINT
-18.0
HUMID 75%RH
RETURN
-18.1
UNIT
ON/OFF
LCD panel
LED light
Operation key
HPT & LPT *3
*1
Supply air temp. is displayed in chilled mode.
*2
Return air temp. is displayed in chilled mode.
*3
Other sensor values can be checked in
"Sensor Information" menu.
ALARM LED
ALARM
IN RANGE
DEFROST
DEHUMID
IN RANGE LED
DEFROST LED
DEHUMID LED
02章01-18LX10F11B3TR16-02En.indd2-202章01-18LX10F11B3TR16-02En.indd2-2 2016/02/0316:14:262016/02/0316:14:26
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LX10F11B3 and is the answer not in the manual?

Daikin LX10F11B3 Specifications

General IconGeneral
BrandDaikin
ModelLX10F11B3
CategoryInverter
LanguageEnglish

Related product manuals