Functions SiUS091133
3 List of Functions
Category Functions
FTXS30/36LVJU
RKS30/36LVJU
FTXS30/36LVJU
RXS30/36LVJU
Category Functions
FTXS30/36LVJU
RKS30/36LVJU
FTXS30/36LVJU
RXS30/36LVJU
Basic
Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°FDB)
14 ~
114.8
14 ~
114.8
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°FWB) —
5 ~
64.4
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control
Titanium Apatite Photocatalytic
Air-Purifying Filter
Compressor Oval Scroll Compressor — — Air Filter (Prefilter)
Swing Compressor Wipe-Clean Flat Panel
Rotary Compressor — — Washable Grille — —
Reluctance DC Motor MOLD PROOF Operation — —
Comfortable
Airflow
Power-Airflow Louver (Horizontal
Blade)
— — Heating Dry Operation — —
Power-Airflow Dual Louvers Good-Sleep Cooling Operation — —
Power-Airflow Diffuser — — Timer WEEKLY TIMER
Wide-Angle Fins (Vertical Blades) 24-Hour ON/OFF TIMER
Vertical Auto-Swing (Up and Down) NIGHT SET Mode
Horizontal Auto-Swing (Right and Left) Worry
Free
“Reliability
&
Durability”
Auto-Restart (after Power Failure)
3-D Airflow Self-Diagnosis (Digital, LED) Display
COMFORT AIRFLOW Operation Wiring Error Check Function — —
Comfort
Control
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat
Exchanger
Indoor Unit Quiet Operation Flexibility Multi-Split / Split Type Compatible Indoor Unit — —
NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit
OUTDOOR UNIT QUIET Operation
(Manual)
Flexible Power Supply Correspondence — —
INTELLIGENT EYE Operation Chargeless
32.8
ft
32.8
ft
Quick Warming Function
(Preheating Operation)
— Either Side Drain (Right or Left)
Hot-Start Function — Power Selection — —
Automatic Defrosting — Low Temperature Cooling Operation
Operation
Automatic Operation —
°F/°C Changeover R/C Temperature Display
(factory setting : °F)
Program Dry Function Remote
Control
5-Rooms Centralized Controller (Option)
Fan Only
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Remote Control Adaptor
(Normal Open Contact) (Option)
Inverter POWERFUL Operation DIII-NET Compatible (Adaptor) (Option)
Priority-Room Setting — — Remote
Controller
Wireless
COOL / HEAT Mode Lock — — Wired (Option)
HOME LEAVE Operation — —
ECONO Operation
Ultra low
ambient
cooling
function
Cooling to - 40°F/-40°C with field installed
accessory kit RK530/36LVJU only
—
Indoor Unit [ON/OFF] Button
Signal Receiving Sign
R/C with Back Light
Temperature Display — —
Note: : Holding Functions