Outdoor Unit: RXS15/18LVJU SiUS091133
293 Removal Procedure
5.2 Removal of Outdoor Fan / Fan Motor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Remove the drip proof
cover.
Preparation
Remove the top panel and the
front panel according to the
“Removal of Outer Panels”.
2
Disconnect the
connector for the fan
motor [S70].
3
Release the clamp from
the partition plate.
The ferrite core of the fan motor
lead wire has a clamp.
Drip proof cover
(R17049)
(R16951)
[S70]
Ferrite core
Partition plate
(R16952)