EasyManuals Logo
Home>Danfoss>Engine>H1B 060

Danfoss H1B 060 Service Manual

Danfoss H1B 060
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
Replace speed sensor
Removal
1. Using a 5 mm internal hex wrench, remove screw (J0020).
2. Remove speed sensor (J0010).
3. Discard O-ring (J0010A).
Assembly
Speed sensor assembly
J0020
J0010A
J0010
5 mm
8 N•m [6 lbf•ft]
1. Lubricate and install new O-ring (J0010A).
2. Install speed sensor (J0010).
3. Install screw (J0020) using a 5 mm internal hex wrench with torque to 8 N•m [6 lbf•ft].
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Minor repair
62 |
©
Danfoss | August 2018 AX00000025en-US0504