Control (U
S
) for standard mounted PVEH /PVEM float B, 4–pin version
Function Voltage relative PWM
Neutral 0,5 • U
DC
50%
Q: P A 0,5 0,34 • U
DC
50% 34%
Q: P B 0,5 0,65 • U
DC
50% 65%
Float 0,75 • U
DC
75%
PVEM is not PLUS+1
®
compliant.
PVE standard connections
AMP version
Hirschmann/DIN
Used for PVEA/PVEH/PVES/PVEU.
Used for PVEH/PVEM/PVES/PVEH float B/PVEM float
B.
Deutsch version
LED
Used for PVEA/PVEH/PVES/PVEU/PVEH float B.
Standard PVE with DI
Connection PVE with direction indication (DI)
Connector 1 U
S
U
DC1
Gnd Error
AMP (grey) p 1 p 2 p 3 p 4
Deutsch p 1 p 4 p 3 p 2
Connector 2 DI-B DI-A Gnd U
DC2
AMP (black) p 1 p 2 p 3 p 4
Deutsch p 4 p 3 p 2 p 1
Technical Information PVE, Series 4 for PVG 32/100/120 and PVHC
Technical Data
520L0553 • Rev GD • Jan 2014 43