PVED-CLS valve calibration data
Navigate to the valve calibration section via System Navigator > Configuration > Valve Calibration
Data
Example parameter settings
Parameter Condition for value change
P3162 If using an EHPS, set the value to -700. Otherwise, use default value.
P3164 If using an EHPS, set the value to 700. Otherwise, use default value.
P3166 Adjust toward 0 for smaller minimum flow in Closed Loop modes (auto-guidance) and vice versa. See deadband figure
below.
P3168 Adjust toward 0 for smaller minimum flow in Closed Loop modes (auto-guidance) and vice versa. See deadband figure
below.
P3170 Can be decreased but do not increase.
Application Guide
PVED-CLS startup guide
Parameter setting
20 |
©
Danfoss | October 2018 AB285975085591en-000101