PVED-CLS GPS configuration
Navigate to the GPS configuration section via System Navigator > Configuration > GPS Config
These parameters only apply if GPS is enabled. GPS Flow Limitation is used with auto-guidance to restrict
the maximum flow to steering cylinders as the vehicle speed increases. See Section 12.5 Vehicle Speed
Dependent Flow Command Limitation in the User Manual for more info.
Parameter Conditions for value change
P3451 Set to desired flow limit [IR, 1000=100%] at 0 km/h (see graph below)
P3453 Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3455)
P3455 Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3453)
P3457 Set to desired vehicle speed in km/h (x-axis) at desired flow limit (P3459)
P3459 Set to desired flow limit (y-axis) at desired vehicle speed in km/h (P3457)
There are three subsets of GPS tuning that will need configuring if GPS is enabled.
Approve the parameters by following the steps in PVED-CLS parameter acceptance on page 8.
PVED-CLS example of GPS flow limitation
Application Guide
PVED-CLS startup guide
Parameter setting
©
Danfoss | October 2018 AB285975085591en-000101 | 33