EasyManuals Logo
Home>Danfoss>Control Unit>PVG 32

Danfoss PVG 32 User Manual

Danfoss PVG 32
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
PVHC for PVG 16
5 [0.197]
8 ±0.5 Nm
[70 ±4.4 lbf •in]
The seal in the PVHC connector and the seals for individual conductors are crucial for correctly sealing the
conductor.
U
DC
(A)
U
DC
(B)
Technical data
Controller output current range 12 V 0 – 1200 mA
24 V 0 – 600 mA
Coil resistance 12 V 1.0 Ω ± 5%
24 V 0.25 Ω ± 5%
Pilot pressure (over tank)
1
Nominal 25 bar [363 psi]
Minimum 21 bar [305 psi]
Maximum 25 bar [363 psi]
Control pressure Range 5 - 15 bar [72.5 - 217.5 psi]
Maximum tank pressure Port T Static 25 bar [363 psi]
Port T Dynamic 30 bar [435 psi]
Temperature range Ambient -30°C to 80°C [-22 to 176°F]
Medium -20°C to 80°C [-4 to 176°F]
Oil viscosity Range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 400 mm2/s [2130 SUS]
Enclosure – Protection class DEUTSCH DT IP 67
Filtering in the hydraulic system;
Max. permissible degree of contamination
23/19/16 (ISO 4406, 1999 version)
1
Designed to be used with hydraulic activated spools
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018 AX284661889190en-000101 | 21

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals