6.3.20 22-** Application Functions
Par.
No. #
Parameter description Default value 4-set-up Change dur-
ing operation
Conver-
sion index
Type
22-0* Miscellaneous
22-00 External Interlock Delay 0 s All set-ups TRUE 0 Uint16
22-01 Power Filter Time 0.50 s 2 set-ups TRUE -2 Uint16
22-2* No-Flow Detection
22-20 Low Power Auto Set-up [0] Off All set-ups FALSE - Uint8
22-21 Low Power Detection [0] Disabled All set-ups TRUE - Uint8
22-22 Low Speed Detection [0] Disabled All set-ups TRUE - Uint8
22-23 No-Flow Function [0] Off All set-ups TRUE - Uint8
22-24 No-Flow Delay 10 s All set-ups TRUE 0 Uint16
22-26 Dry Pump Function [0] Off All set-ups TRUE - Uint8
22-27 Dry Pump Delay 10 s All set-ups TRUE 0 Uint16
22-3* No-Flow Power Tuning
22-30 No-Flow Power 0.00 kW All set-ups TRUE 1 Uint32
22-31 Power Correction Factor 100 % All set-ups TRUE 0 Uint16
22-32 Low Speed [RPM] SR All set-ups TRUE 67 Uint16
22-33 Low Speed [Hz] SR All set-ups TRUE -1 Uint16
22-34 Low Speed Power [kW] SR All set-ups TRUE 1 Uint32
22-35 Low Speed Power [HP] SR All set-ups TRUE -2 Uint32
22-36 High Speed [RPM] SR All set-ups TRUE 67 Uint16
22-37 High Speed [Hz] SR All set-ups TRUE -1 Uint16
22-38 High Speed Power [kW] SR All set-ups TRUE 1 Uint32
22-39 High Speed Power [HP] SR All set-ups TRUE -2 Uint32
22-4* Sleep Mode
22-40 Minimum Run Time 10 s All set-ups TRUE 0 Uint16
22-41 Minimum Sleep Time 10 s All set-ups TRUE 0 Uint16
22-42 Wake-up Speed [RPM] SR All set-ups TRUE 67 Uint16
22-43 Wake-up Speed [Hz] SR All set-ups TRUE -1 Uint16
22-44 Wake-up Ref./FB Difference 10 % All set-ups TRUE 0 Int8
22-45 Setpoint Boost 0 % All set-ups TRUE 0 Int8
22-46 Maximum Boost Time 60 s All set-ups TRUE 0 Uint16
22-5* End of Curve
22-50 End of Curve Function [0] Off All set-ups TRUE - Uint8
22-51 End of Curve Delay 10 s All set-ups TRUE 0 Uint16
22-6* Broken Belt Detection
22-60 Broken Belt Function [0] Off All set-ups TRUE - Uint8
22-61 Broken Belt Torque 10 % All set-ups TRUE 0 Uint8
22-62 Broken Belt Delay 10 s All set-ups TRUE 0 Uint16
22-7* Short Cycle Protection
22-75 Short Cycle Protection [0] Disabled All set-ups TRUE - Uint8
22-76 Interval between Starts
start_to_start_min_on_time
(P2277) All set-ups TRUE 0 Uint16
22-77 Minimum Run Time 0 s All set-ups TRUE 0 Uint16
22-78 Minimum Run Time Override [0] Disabled All set-ups FALSE - Uint8
22-79 Minimum Run Time Override Value 0.000 ProcessCtrlUnit All set-ups TRUE -3 Int32
22-8* Flow Compensation
22-80 Flow Compensation [0] Disabled All set-ups TRUE - Uint8
22-81 Square-linear Curve Approximation 100 % All set-ups TRUE 0 Uint8
22-82 Work Point Calculation [0] Disabled All set-ups TRUE - Uint8
22-83 Speed at No-Flow [RPM] SR All set-ups TRUE 67 Uint16
22-84 Speed at No-Flow [Hz] SR All set-ups TRUE -1 Uint16
22-85 Speed at Design Point [RPM] SR All set-ups TRUE 67 Uint16
22-86 Speed at Design Point [Hz] SR All set-ups TRUE -1 Uint16
22-87 Pressure at No-Flow Speed 0.000 N/A All set-ups TRUE -3 Int32
22-88 Pressure at Rated Speed 999999.999 N/A All set-ups TRUE -3 Int32
22-89 Flow at Design Point 0.000 N/A All set-ups TRUE -3 Int32
22-90 Flow at Rated Speed 0.000 N/A All set-ups TRUE -3 Int32
VLT HVAC Low Harmonic Drive Operating In-
structions 6 How to Programme the Low Harmonic Drive
MG.16.A1.02 - VLT
®
is a registered Danfoss trademark 141
6

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals