VLT
®
FCD Series
The LCP 2 control unit, option
The FCD 300 can be combined with an LCP control
unit (Local Control Panel - LCP 2) which makes up a
complete interface for operation and pro
gramming of
the frequency converter. The LCP 2 control unit can
be attached up to three metres from the frequency
converter, e.g. on a front panel, usin
g an accessory kit.
The control panel is divided into f
ive functional groups:
1. Display.
2. Keys used to change the display function.
3. Keys used to change the programme par
ameters.
4. Indicator lamps.
5. Local control keys.
Alldataisdisplayedviaa4-linealphanumeric
display, which during normal ope
ration will be able
to continuously display 4 items of operating data
and 3 operating modes. During programming all
information needed for quick,
effective parameter
setup of the frequency converter will be displayed. As
asupplementtothedisplay,therearethreeindicator
lamps for voltage (ON), w
arning (WARNING) and alarm
(ALARM). All frequency converter parameter Setups
can be changed immediately from the control panel,
unless this function h
as been programmed as Locked
[1] via parameter 018 Lock for data c hanges.
Control keys for parameter Setup
The control keys are divided into functions, in
such a way that the keys between the display
and the indicator lamps are used for parameter
Setup, including selection of the displaysview
mode during normal operation.
[DISPLAY/STATUS] is used to select the displays
view mode or to change back to Display mode
from either Quick Menu or Menu mode.
[QUICK MENU] provides access to the parameters
used in the Quick Menu. It is possible to switch
between Quick Menu and Menu mode.
[MENU] givesaccesstoallparameters. Itispossible
to switch between Menu mode and Quick Menu.
[CHANGE DATA] is used to change a parameter that
has been selected either in Menu mode or Quick Menu.
[CANCEL] is used if a change to the selected
parameter is not to be implemented.
[OK] is used to confirm a change to a
selected parameter.
[+ / -] are used for selecting parameters and
for changing parameter values.
These keys are also used in Display mode to switch
between the readouts of operating variables.
[< >] are used for selecting parameter group and to
move the cursor when changing a numerical value.
MG.04.B7.02 - VLT is a registered Danfoss trademark
26

Table of Contents

Other manuals for Danfoss VLT FCD 303

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCD 303 and is the answer not in the manual?

Danfoss VLT FCD 303 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCD 303
CategoryDC Drives
LanguageEnglish

Related product manuals