VLT
®
FCD Series
Programming, FCD
300
Load and Motor
Configuration
Selection of configuration and torque characteristics
has an effect on which parameters can be seen in the
display. If Open loop [0] is selected, all parameters
relating to PID regulation will be filtered out. This
means that the user only sees the parameters that
are relevant for a given application.
100 Configuration
(CONFIGURATION)
Value:
Speed control, open loop
(SPEED OPEN LOOP)
[0]
Speed control, closed loop
(SPEED CLOSED LOOP)
[1]
Process control, closed loop
(PROCESS CLOSED LOOP)
[3]
Function:
This parameter is used to select the configuration
to which the frequency converter is to be adapted.
This makes adaptation to a given application
simple, since the parameters not used in a given
configuration are hidden (not active).
Description of choice:
If Speed control, open loop [0] is selected, normal
speed control is obtained (without feedback
signal) with automatic load and slip compensation
to ensure a constant speed at varying loads.
Compensations are active, but may be disabled in
parameter 134 Load compensation and parameter
136 Slip compensation as required.
If Speed control, closed loop [1] is selected, better
speed accuracy is obtained. A feedback signal must
be added, and the PID regulator must be set in
parameter group 400 Special functions.
If Process control, closed loop [3] is selected, the
internal process regulator is activated to enabl
eprecise
control of a process in relation to a given process
signal. The process signal can be set to the relevant
process unit or as a percentage. A feedback sign
al
must be added from the process and the process
regulator must be set in parameter group 400 Special
functions. Process closed loop is not ac
tive if a
DeviceNet card is mounted and Instance 20/70 or
21/71 is chosen in parameter 904 Instance types.
101 Torque characteristic
(TORQUE CHARACT)
Value:
Constant torque
(CONSTANT TORQUE)
[1]
Variable torque low
(TORQUE: LOW)
[2]
Variable torque medium
(TORQUE: MED)
[3]
Variable torque high
(TORQUE: HIGH)
[4]
Variable torque low with CT start
(VT LOW CT START)
[5]
Variable torque medium with CT start
(VT MED CT START)
[6]
Variable torque high with CT start
(VTHIGHCTSTART)
[7]
Special motor mode
(SPECIAL MOTOR MODE)
[8]
CT = Constant torque
Function:
This parameter enables a choice of principle
for adaptation of the U/f ratio of the frequency
converter to the torque characteristic of the
load. See par. 135 U/f ratio.
Description of choice:
If Constant torque [1] is selected, a load-dependent U/f
characteristic is obtained, in which output voltage and
output frequency are increased at increasing loads in
order to maintain constant magnetization of the motor.
Select Variable torque low [2], Variable torque
medium [3] or Variable torque high [4], if the load
is square (centrifugal pumps, fans).
Variable torque - low with CT start [5], -mediumwith
CT start [6] or high with CT start [7], are selected if
you need a greater breakaway torque than can be
achieved with the three first characteristics.
NB!:
Load and slip compensation are not
active if variable torque or special motor
mode have been selected.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.04.B7.02 - VLT is a registered Danfoss trademark
39

Table of Contents

Other manuals for Danfoss VLT FCD 303

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCD 303 and is the answer not in the manual?

Danfoss VLT FCD 303 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCD 303
CategoryDC Drives
LanguageEnglish

Summary

Introduction to FCD 300

Safety Information

Critical safety warnings and guidelines for installation and operation.

Flexible Installation Options

Stand Alone Mounting

Describes mounting the unit separately from the motor.

Motor Mounting Options

Details mounting directly on motor or on Danfoss Bauer motors.

Installation

Mechanical Dimensions and Spacing

Covers mechanical dimensions, spacing, and mounting clearance.

Mechanical Installation Details

Covers separation of parts, gasket tightening, and mounting considerations.

Motor Mounting Considerations

Details on mounting the unit onto the motor, including adaptor plates.

General Electrical Installation

Essential guidelines for safe and compliant electrical installation.

High Voltage Safety Precautions

Reinforces high voltage precautions and safe disconnection procedures.

Cable Routing and Earthing Practices

Guidelines for cable routing, separation, earthing, and screened cables.

EMC and Protection Measures

Discusses EMC compliance, earthing, and extra protection like ELCB relays.

Protective Earth Connection Details

Details the importance and methods of protective earth connection.

EMC-Correct Electrical Installation Practices

Provides general points for ensuring EMC-compliant electrical installations.

ATEX Correct Installation Requirements

Specific requirements for installing the FCD 300 in ATEX zone 22 environments.

Location of Terminals

Identifies terminal locations on the FCD 300 unit.

Terminal Connection Versions

Illustrates terminal layouts for different FCD 300 versions.

Mains and Motor Connection Details

Details mains connection, motor connection, and rotation direction.

Motor Connection Options

Details HAN 10E plug, parallel motors, and motor cable selection.

Motor Thermal Protection

Information on using the electronic thermal relay for motor protection.

Brake Resistor and Mechanical Brake Control

Instructions for connecting brake resistors and controlling mechanical brakes.

Control Cable Electrical Installation

Guidance on installing and terminating control cables, including earth loop prevention.

Sensor Connection to M12 Plugs

Wiring instructions for connecting sensors to M12 plugs for T53, T63, T73.

Control Terminal Electrical Installation

Detailed list of control terminals and their functions.

Programming FCD 300

Start/Stop and Pulse Control Functions

Configuring digital inputs for start/stop and pulse operations.

Preset Reference Configuration

How to configure and use preset references via digital inputs.

Local Control Panel (LCP 2)

Display Modes and Setup Navigation

Explains Display Mode IV and the two parameter setup modes (Menu, Quick Menu).

Quick Menu Operation with LCP 2

How to initiate and navigate the Quick Menu using the LCP 2.

Menu Mode Parameter Selection

How to access and select parameter groups in Menu mode.

Changing Parameter Data and Initialization Procedures

Procedures for changing parameter data and performing manual initialization.

Operation & Display Parameter Settings

Details on Language, Local/Remote Operation, and Local Reference parameters.

Setup Configuration Overview

Explains the concept of Setups and how to manage them.

Setup Management Functions

Covers Setup Shift, Active Setup, Programming Setup, and Setup Copying.

Local Control Configuration Options

Settings for local control modes and their interaction with other parameters.

Parameter 018 Data Change Lock

Preventing unauthorized parameter changes via control keys.

Power-Up Operation and Mode Locking

Defining power-up behavior and locking Hand mode.

Quick Menu Setup Configuration

Defining parameters to be included in the Quick Menu.

Load and Motor Configuration

Motor Nameplate Data Configuration

Setting motor nameplate data for power, voltage, frequency, current, and speed.

References and Limits

Inputs and Outputs

Digital Input Assignments and Functions

Table mapping digital input terminals and parameters to functions, with descriptions.

Serial Communication

Control Word FC Protocol Details

Detailed breakdown of control word bits for FC protocol.

Status Word FC Profile Details

Explains status word bits according to FC profile.

Control Word Fieldbus Profile Details

Control word bits for Fieldbus (Profibus) communication.

Status Word Profidrive Protocol Details

Explains status word bits for Profidrive protocol.

All About FCD 300

Warning and Alarm Message Overview

Lists and describes common warnings and alarms with LED indications.

Safeguards and Protection Mechanisms

Protection mechanisms against overload, short-circuits, voltage issues, and earth faults.

General Technical Data

Mains Supply, Output Data, and Torque Characteristics

Electrical specifications for mains supply, output, and motor torque.

Technical Data: Mains Supply 3 x 380-480 V

Output Current, Power, Cable, and Input Specifications

Electrical and physical specifications for output, input, motor, and power connections.

Factory Settings Overview

Related product manuals