VLT
®
FCD Series
Programming, FCD
300
Function:
See function description of parameter 502
Coasting stop.
Description of choice:
The table below shows which Setup (parameter
004 Active Setup) is selected for each of the
following: Digital input [0], Serial communication
[1], Logic and [2] or Logic or [3].
Digital input [0]
Setup msb Setup lsb Function
0 0 Setup 1
0 1 Setup 2
1 0 Setup 3
1 1 Setup 4
Serial communication [1]
Setup msb Setup lsb Function
0 0 Setup 1
0 1 Setup 2
1 0 Setup 3
1 1 Setup 4
Logic and [2]
Bus Setup
msb
Bus
Setup
lsb
Dig.
Setup
msb
Dig.
Setup
lsb
Setup no.
0 0 0 0 1
0
0 0 1 1
0
0 1 0 1
0
0 1 1 1
0 1 0 0 1
0
1 0 1 2
0
1 1 0 1
0
1 1 1 2
1 0 0 0 1
1
0 0 1 1
1
0 1 0 3
1
0 1 1 3
1 1 0 0 1
1
1 0 1 2
1
1 1 0 3
1
1 1 1 4
Logic or [3]
Bus
Setup
msb
Bus Setup
lsb
Dig.
Setup
msb
Dig.
Setup
lsb
Setup no.
0 0 0 0 1
0
0 0 1 2
0
0 1 0 3
0
0 1 1 4
0 1 0 0 2
0
1 0 1 2
0
1 1 0 4
0
1 1 1 4
1 0 0 0 3
1
0 0 1 4
1
0 1 0 3
1
0 1 1 4
1 1 0 0 4
1
1 0 1 4
1
1 1 0 4
1
1 1 1 4
508 Selection of preset ref.
(PRES.REF. SELECT)
Value:
Digital input (DIGITAL INPUT)
[0]
Serial comunication (SERIAL PORT)
[1]
Logic and (LOGIC AND)
[2]
✭Logic or (LOGIC OR)
[3]
Function:
See function description of parameter 502
Coasting stop.
Description of choice:
Preset references via serial communication are
active when parameter 512 Telegram profile
is set to FC protocol [1].
509 Busjog1(BUSJOG1FREQ.)
510 Busjog2(BUSJOG2FREQ.)
Value:
0.0 - par. 202 Output frequency high l imit
✭ 10,0 Hz
Function:
If parameter 512 Telegram Profile shows the selection
Profidrive [0], two fixed speeds (Jog 1 or Jog 2)
can be selected via the serial port.
The function is the same as in parameter
213 Jog frequency .
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.04.B7.02 - VLT is a registered Danfoss trademark