By using the hardware switches it is possible to set 253
different station names according to Table 3.3 (FC 302 used
in this example):
Switch 8 7 6 5 4 3 2 1
12-08 Host Name
+128 +64 +32 +16 +8 +4 +2 +1
‘FC-302-005’ OFF OFF OFF OFF OFF ON OFF ON
‘FC-302-035’ OFF OFF ON OFF OFF OFF ON ON
‘FC-302-082’ OFF ON OFF ON OFF OFF ON OFF
‘FC-302-212’ ON ON OFF ON OFF ON OFF OFF
Table 3.3 Host Names Setting
The Host Name change comes into effect at the next
power-up, and can be read in 12-08 Host Name.
3.3 LED Behaviour
The option has 3 bi-coloured LEDs that allow a fast and
detailed diagnosis. The 3 LEDs are each linked to its
unique part of the PROFINET option, see Table 3.4.
LED label Description
MS Module Status, reflects the activity on the
PROFINET stack
NS1 Network Status 1, reflects the activity on port 1
NS2 Network Status 2, reflects the activity on port 2
Table 3.4 LED Label
Illustration 3.14 LED Panel for FCD 302
The LED is visible from the outside of an FCD 302.
How to Install
Operating Instructions