No. Description Warning Alarm/trip Alarm/trip lock Parameter reference
22 Hoist Mech. Brake
23 Internal Fan Fault X
24 External Fan Fault X
14-53 Fan Monitor
25 Brake resistor short-circuited X
26 Brake resistor power limit (X) (X)
2-13 Brake Power Monitoring
27 Brake chopper short-circuited X X
28 Brake check (X) (X)
2-15 Brake Check
29 Heatsink temp X X X
30 Motor phase U missing (X) (X) (X)
4-58 Missing Motor Phase Function
31 Motor phase V missing (X) (X) (X)
4-58 Missing Motor Phase Function
32 Motor phase W missing (X) (X) (X)
4-58 Missing Motor Phase Function
33 Inrush Fault X X
34 Fieldbus communication fault X X
36 Mains failure X X
38 Internal Fault X X
39 Heatsink sensor X X
40 Overload of Digital Output Terminal 27 (X)
5-00 Digital I/O Mode,
5-01 Terminal 27 Mode
41 Overload of Digital Output Terminal 29 (X)
5-00 Digital I/O Mode,
5-02 Terminal 29 Mode
42 Overload of Digital Output On X30/6 (X)
5-32 Term X30/6 Digi Out (MCB 101)
42 Overload of Digital Output On X30/7 (X)
5-33 Term X30/7 Digi Out (MCB 101)
46 Pwr. card supply X X
47 24 V supply low X X X
48 1.8 V supply low X X
49 Speed limit X
50 AMA calibration failed X
51 AMA check U
nom
and I
nom
X
52 AMA low I
nom
X
53 AMA motor too big X
54 AMA motor too small X
55 AMA parameter out of range X
56 AMA interrupted by user X
57 AMA time-out X
58 AMA internal fault X X
59 Current limit X
61 Tracking Error (X) (X)
4-30 Motor Feedback Loss Function
62 Output Frequency at Maximum Limit X
63 Mechanical Brake Low (X)
2-20 Release Brake Current
64 Voltage Limit X
65 Control Board Over-temperature X X X
66 Heat sink Temperature Low X
67 Option Configuration has Changed X
68 Safe Stop (X)
(X)
1)
5-19 Terminal 37 Safe Stop
69 Pwr. Card Temp X X
70 Illegal FC configuration X
71 PTC 1 Safe Stop X
X
1)
5-19 Terminal 37 Safe Stop
72 Dangerous Failure
X
1)
5-19 Terminal 37 Safe Stop
73 Safe Stop Auto Restart
77 Reduced power mode X
14-59 Actual Number of Inverter
Units
79 Illegal PS config X X
Warnings and Alarms Operating Instructions
70 Danfoss A/S © Rev. 2014-02-27 All rights reserved. MG90U302
1111

Table of Contents

Other manuals for Danfoss VLT PROFINET MCA 120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT PROFINET MCA 120 and is the answer not in the manual?

Danfoss VLT PROFINET MCA 120 Specifications

General IconGeneral
BrandDanfoss
ModelVLT PROFINET MCA 120
CategoryDC Drives
LanguageEnglish

Related product manuals