INSTALLATION DRAWINGS
WA634ACH/ACL
DIMENSIONS mm
ISSUE 8
TOP VIEW
SIDE VIEW REAR VIEW FRONT VIEW
AIR OFF
785
705
500
156
202
CONDENSATE
172
213
305
FLOW
GAUGE
VIEWING
WINDOW
WATER OUT
WATER IN
3/4 BSPM
STUBS
258
145
287
192
35
500
760
116
70
596
70
CONSOLE
92
MAINS IN
AT SIDE
HP RESET
BUTTON
LP CHILL LIMIT
RESET BUTTON
AIR ON
AREA REQUIRED FOR
SERVICE ACCESS
AREA REQUIRED FOR
SERVICE ACCESS
41