POWERSCAN® D8330/M8300/M8300-DK
5.14.3 Copy BC-80X0
Using the slave reader and its BC-80X0 cradle, read the Restore Default
barcode, set the radio address, and then read the RS-232 interface barcode
4
from chapter of this manual or from the Quick Reference Guide.
Connect the master BC-80X0 and the slave BC-80X0 (cradle to be configured)
together through two RS-
232 serial interface cables and external power supply.
Accessory cables and power supply are available from your Datalogic
distributor to provide this connection.
RS-232 Cables:
CAB471 & CAB472
Read the Configuration Copy barcode below with a reader. Then place it onto
the master BC-80X0 cradle.
Copy Configuration
The configuration will be copied from the master BC-80X0 to the slave
BC-80X0. The reader signals the end of the procedure with a series of beeps.
Repeat the procedure above to configure other slave cradles.
NOTE: The master BC-80X0 can be configured for any interface.