Enter Configuration
Exit and Save Configuration
Ì$+;Î
POWER SAVE
Ì$-?Î
82
SLEEP STATE
disable
ÌBQ0nÎ
enable
ÌBQ1qÎ
See par. 5.5.1 for details.
For M8300 series readers, sleep state is entered immediately after reading a code and is not
configurable.
ENTER SLEEP TIMEOUT
enter sleep timeout
ÌBR@Î
Read 2 numbers in the range 00-99:
00 = Enter Sleep state immediately
01-99 = corresponds to a max. 9.9 sec. delay before entering the
Sleep state.
enter sleep timeout = 0.6 sec.
See par. 5.5.2 for details.