Enter/Exit Programming Mode Code 11
156 QuickScan™ I QD24XX/QBT24XX/QM24XX
Code 11 Set Length 2
This feature specifies one of the bar code lengths for Code 11 Length Control on page 154.
Length 2 is the maximum label length if in Variable Length on page 243 Mode, or the second
fixed length if in Fixed Length on page 243 Mode. Length includes the bar code’s check and
data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(onl
y one fixed length).
Table 16 provides examples for setting Length 2. See page 243 for detailed instructions on set-
ting this feature.
Table 16. Code 11 Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (pad with
leading zeroes)
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 11 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ and 0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters