Enter/Exit Programming Mode
194 QuickScan™ I QD24XX/QBT24XX/QM24XX
PDF417
PDF417 Enable / Disable
Enables/disables the ability of the reader to decode PDF417 labels.
PDF417 = Disable
PDF417 = Enable
PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbol-
ogy.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
PDF417 Length Control = Variable Length
PDF417 Length Control = Fixed Length