1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
167
Code 93 Set Length 1
Specifies one of the bar code lengths for Code 93 Length Control on page 166. Length 1 is the
minimum label length if in Variable Length on page 243 Mode, or the first fixed length if in
Fixed Length on page 243 Mode. Length includes the bar code’s data characters only. The
le
ngth can be set from 01 to 50 characters.
Table 19 provides some examples for setting Length 1. See page 243 for detailed instructions
on setting this feature.
Table 19. Code 93 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT24 series and is the answer not in the manual?

Datalogic QuickScan QBT24 series Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan QBT24 series
CategoryBarcode Reader
LanguageEnglish

Related product manuals