Enter/Exit Programming Mode Industrial 2 of 5
142 QuickScan™ I QD24XX/QBT24XX/QM24XX
Industrial 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control on page
140. Length 2 is the maximum label length if in Variable Length on page 113 Mode, or the sec-
ond fixed length if in Fixed Length on page 113 Mode. Length includes the bar code’s check,
da
ta, and full-ASCII shift characters. The length does
not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length
(onl
y one fixed length).
Table 12 provides examples for setting Length 2. See page 243 for detailed instructions on set-
ting this feature.
Table 12. Industrial 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CU2L2
Select Industrial 2 of5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QD24 series and is the answer not in the manual?

Datalogic QuickScan QD24 series Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan QD24 series
CategoryBarcode Reader
LanguageEnglish

Related product manuals