Scanning Features
Product Reference Guide
255
Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after pulling the trigger
when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms
to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits.
For example: 2 = 02, 5 = 05, 20 =
20, etc.
3. Go to page 79 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5
. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the
setting which was determined in the steps above. You will hear a two-beep indication after
the la
st character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 38 for some examples of how to set this feature.
Table 38. Stand Mode Off Time
STEP ACTION EXAMPLES
1 Desired Setting
500 ms 1 Second 5.5 Seconds 16 Seconds
2 Pad leading zero
01 02 11 32
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1 ‘0’ and ‘2’ ‘1’ and ‘1’ ‘3’ and ‘2’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QD24 series and is the answer not in the manual?

Datalogic QuickScan QD24 series Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan QD24 series
CategoryBarcode Reader
LanguageEnglish

Related product manuals