Enter/Exit Programming Mode
36
QuickScan™ I QD24XX/QBT24XX/QM24XX
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
See page 236 for more information on setting this feature.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left fol-
lowed by the digits from the Alphanumer
ic characters in
Appendix D, Keypad
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar cod
e again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and
a selection of 255 specifies unlimited retries. See page 237 for more information.
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left fol-
lowed by the digits from the Alphanumer
ic characters in
Appendix D, Keypad
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar cod
e again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT