MIOX AE Series Operators Manual
102-00085-E Page 18
Brine Feed Connection
The brine feed connection to the AE™ Series OSG is 3/8” tube with the appropriate adapter fitting. The
OSG is equipped with a 3/8” barb fitting on the inlet of the brine filter assembly. Connection to the barb
fitting is made with 3/8” ID x 5/8” OD flexible clear tubing supplied in the operations kit. A primer bulb
is also included in the operations kit and should be placed in-line upstream of filter assembly but as
close to the unit as possible. The primer bulb will aid in removing air bubbles for brine delivery to the
cell. (Figure 5)
Figure 5 Brine Feed Connection
Note: On initial start-up, cell replacement or when brine plumbing connections are modified,
air is introduced to the brine line. This air must be removed for proper operation of the brine
pump. Air locks in the brine line will prohibit consistent brine flow to the cell.
Brine Inlet
Primer Bulb