MIOX AE Series Operators Manual
102-00085-E Page 35
Maintenance Guide
The AE™ Series OSG should be monitored periodically to ensure that the unit is running properly. MIOX
Corporation recommends daily, weekly, monthly, and quarterly checks. In order to maintain a history of
system performance and assist in troubleshooting and warranty work, it is recommended that a log be
kept near the OSG for easy record keeping. It is recommended that Appendix D – MIOX System Log
Sheet included in this manual be copied and used for this purpose.
SAFETY PRECAUTIONS AND WARNINGS
Disconnect power before working on OSG.
Do not defeat or tamper with electrical interlocks or lockout mechanisms.
Proper venting of the oxidant tank is mandatory. Refer to MIOX Corporation’s
Hydrogen Safety
White Paper.
NO flames or ignition sources in or around the oxidant tank.
Use confined space procedures prior to entry to the oxidant tank.
Do not add other chemicals to the oxidant tank.
Always follow the plumbing and venting procedures recommended by MIOX Corporation
and your local codes. Consult MIOX Corporation or an engineering professional prior to
making changes to piping in oxidant tank.