Installing System Components 143
10 Using a #2 Phillips screwdriver, tighten the heat-sink retention screws.
See
Figure 3-26
.
11
Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 91.
12
Close the system. See "Closing the System" on page 89.
13
Reconnect the system to its electrical outlet and turn the system on,
including any attached peripherals.
14
Press <F2> to enter the System Setup program, and check that the processor
information
matches the new system configuration. See "Entering the
System Setup Program" on page 62.
15
Run the system diagnostics to verify that the new processor operates
correctly.
See "Running the Embedded System Diagnostics" on page 190 for
information about running the diagnostics.
System Battery
Replacing the System Battery
WARNING: There is a danger of a new battery exploding if it is incorrectly
installed. Replace the battery only with the same or equivalent type recommended
by the manufacturer. See your safety information for additional info.
CAUTION: Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.
1
Turn off the system, including any attached peripherals,
and disconnect the system from the electrical outlet.
2
Open the system. See "Opening the System" on page 87.
3
Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 90.
book.book Page 143 Friday, November 20, 2009 2:56 PM

Table of Contents

Other manuals for Dell PowerEdge R510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R510 and is the answer not in the manual?

Dell PowerEdge R510 Specifications

General IconGeneral
HDD size3.5 \
Hot-swapYes
HDD capacity450 GB
HDD interfaceSerial Attached SCSI (SAS)
Total storage capacity900 GB
Number of HDDs installed2
Number of HDDs supported8
Internal memory4 GB
Memory clock speed1066 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory64 GB
Tcase76 °C
Bus typeQPI
SteppingD0
FSB ParityNo
Processor codeSLBF6
Processor cache8 MB
Processor cores4
Processor modelE5540
System bus rate5.86 GT/s
Processor seriesIntel Xeon 5500 Series
Processor socketSocket B (LGA 1366)
Processor codenameNehalem EP
Motherboard chipsetIntel® 5500
Processing Die size263 mm²
Processor frequency2.53 GHz
Processor cache typeSmart Cache
Processor lithography45 nm
Processor system typeDP
Processor manufacturerIntel
Processor package size42.5 x 45 mm
Processor front side bus- MHz
Processor boost frequency2.8 GHz
Processor operating modes64-bit
Thermal Design Power (TDP)80 W
CPU multiplier (bus/core ratio)19
Number of Processing Die Transistors731 M
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25.6 GB/s
Maximum internal memory supported by processor144 GB
PS/2 ports quantity0
Serial ports quantity1
USB 2.0 ports quantity6
DisplayLCD
L1 cache0.064 MB
Form factor-
Graphics cardG200eW
Dimensions (WxDxH)86.4 x 436.6 x 609.6 mm
Compatible operating systemsMicrosoft Windows Small Business Server 2008/2003/ Novell SUSE Linux Enterprise Server 11/10 SP2 Linux Red Hat Enterprise 5.3/4.7 VMware vSphere Version 4.0 VMware ESX v3.5 / ESXi v3.5
Power consumption (typical)1100 W
Noise level42 dB
Chassis typeRack (2U)
PCI Express x4 slots3
Processor ARK ID37104
Intel® Turbo Boost Technology1.0
Weight and Dimensions IconWeight and Dimensions
Weight13500 g