Chapter 7 Servo Parameters|ASDA-B Series
7-72 Revision January, 2009
Reserve / Clear Memory Block Function Settings
0: Reserve memory block
1: Clear memory block
When the clear memory block function is selected, the memory block will be cleared.
This parameter setting will return to its default setting after clear function is executed successfully.
P8 - 12
KRNO Memory Block Position Number (ROMx) Communication Addr.: 080CH
Default: 0 Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 24
This parameter is used to determine the memory block number (ROMx) shown on the keypad
display.
P8 - 13
KBL0 Status of Memory Block (ROMx) Communication Addr.: 080DH
Default: 0 Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 23999
Settings:
ASD-PU-01A ASD-PU-01B
Drive Rated Power Settings:
002: 200W
003: 400W (F604)
004: 750W
005: 1kW
006: 1.5kW
007: 2kW
103: 400W(F804)
Motor Inertia Settings:
1: Low inertia
2: Medium inertia
3: High inertia
Drive Series Settings:
1: ASDA-A series
2: ASDA-B series
This parameter displays the status of memory block number (ROMx) by referring the setting of
parameter P8-12.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-B Series and is the answer not in the manual?

Delta Electronics ASDA-B Series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-B Series
CategoryDC Drives
LanguageEnglish

Related product manuals