Type
Error Code
in SR1605
Error Message Solution
for backup/restoration local authorized distributors of the
Delta drive.
H’1108
Device responds with an unexpected
error.
Check if the network cable is
well-connected and free from noise
interference.
Restoration
error
H’2000 Parameters exceed the upper limit.
If the problem persists, contact the
local authorized distributors of the
Delta drive.
H’2001 Parameters are less than the lower limit.
If the problem persists, contact the
local authorized distributors of the
Delta drive.
H’2002 Parameters can NOT be written.
If the problem persists, contact the
local authorized distributors of the
Delta drive.
H’2003
Currently the device is at the state of
RUN.
Switch the device to the state of STOP.
H’2004
Currently the device is at the state of
error.
Refer to the drive user manual for more
information.
H’2005 Incorrect device file
If the problem persists, contact the
local authorized distributors of the
Delta drive.
H’2006
Number of device parameters not
matched.
If the problem persists, contact the
local authorized distributors of the
Delta drive.
H’2007
Execution of backup or restoration
timeout
If the problem persists, contact the
local authorized distributors of the
Delta drive.
13.3.5 FAQ
Question 1: Is Ethernet/IP the only communication protocol for backup and restoration?
Answer: Yes, currently Ethernet/IP is the only communication protocol supported. RS485 communicaiton will also be
available in the near future.
Question 2: Are the file name and the folder path editable?
Answer: The file name of the backup file contains to 4 sections, PLC Ethernet communication port, Ethernet
communication protocol, and device information. Only the device information can be edited according to the device to be
restored. See below for more details on the file naming.
File naming: mmmm_nn_tt_pppppppppppppppp.par
nn: communication port number (e.g. PLC Ethernet communication port is 03.)
tt: communication protocol type (e.g. Ethernet communication is fixed to 01.)
pppppppppppppppp: device information (IP + ID + 000000 in the hexadecimal format)
For example: If the device IP is 192.168.1.101 and its ID is 01, the device information is C0A80165
(IP: 192 = 16#C0, 168=16#A8, 1=16#01, 101=16#65) + 01 (ID) + 000000 = C0A8016501000000.par
Question 3: Can backup and restoration be executed when PLC CPU is at the state of RUN?
Answer: No. Backup and restoration can only be executed when PLC CPU is at the state of STOP. Since AS Series PLC
CPU reads data from or writes data into the SD card, it affects the PLC scan time and may further affect the PLC
operation.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS332P-A and is the answer not in the manual?

Delta AS332P-A Specifications

General IconGeneral
BrandDelta
ModelAS332P-A
CategoryControl Unit
LanguageEnglish

Related product manuals