ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-55
P1-04 MON1 MON1 Analog Monitor Output Proportion
Address: 0108H
0109H
Operational
Interface:
Panel / Software Communication
Related Section:
6.4.4
Default:
100
Control
Mode:
ALL
Unit:
% (full scale)
Range:
0 ~ 100
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to parameter P0-03 for the setting of analog output
selection.
For example:
P0-03 = 0x00 (MON1 is the speed analog output)
When the output voltage value of MON1 is V1:
Motor speed = (Max. speed × V1/8) × P1-04/100
P1-05 MON2 MON2 Analog Monitor Output Proportion
Address: 0108H
0109H
Operational
Interface:
Panel / Software Communication
Related Section:
6.4.4
Default:
100
Control
Mode:
ALL
Unit:
% (full scale)
Range:
0 ~ 100
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to parameter P0-03 for the setting of analog output
selection.
For example:
P0-03 = 0x00 (MON2 is the speed analog output)
When the output voltage value of MON2 is V2:
Motor speed = (Max. × V2/8) × P1-05/100

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals