Chapter 8 Parameters ASDA-A2
8-92 Revision February, 2017
P2-02 PFG Position Feed Forward Gain
Address: 0204H
0205H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.8
Default
50
Control
Mode
PTPR
Unit
%
Range
0 ~ 100
Data Size
16-bit
Format
Decimal
Settings
If the position command is changed smoothly, increasing the gain
value can reduce the position error.
If the position command is not changed smoothly, decreasing the gain
value can tackle the problem of mechanical vibration.
P2-03 PFF
Smooth Constant of Position Feed Forward
Gain
Address: 0206H
0207H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
5
Control
Mode
PTPR
Unit
ms
Range
2 ~ 100
Data Size
16-bit
Format
Decimal
Settings
If the position command is changed smoothly, decreasing the value
can reduce the position error. If the position command is not changed
smoothly, increasing the value can tackle the problem of mechanical
vibration.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals