ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-93
P2-04 KVP Speed Loop Gain
Address: 0208H
0209H
Operational
Interface:
Panel / Software Communication
Related Section:
6.3.6
Default:
500
Control
Mode:
ALL
Unit:
rad/s
Range:
0 ~ 8191
Data Size:
16-bit
Format:
Decimal
Settings:
Increase the value of speed loop gain can enhance the speed
response. However, if the value is set too big, it would easily cause
resonance and noise.
P2-05 SPR Switching Rate of Speed Loop Gain
Address: 020AH
020BH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
100
Control
Mode:
ALL
Unit:
%
Range:
10 ~ 500
Data Size:
16-bit
Format:
Decimal
Settings:
Switch the changing rate of speed loop gain according to the gain
switching condition.