E-Cam degree
P2-79
P2-78
360°
DO:CAM_AREA2 ON ON OFF OFF OFF ON ON
When the E-Cam is not engaged, the status of digital output,
CAM_AREA2 is always OFF.
P2-80 Z Phase Source of Homing
Address: 02A0H
02A1H
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0x0000
Control
Mode
PR
Unit
-
Range
0x0000 ~ 0x0011
Data Size
16-bit
Format
Hexadecimal
Setting
Z phase source of full-closed loop homing
0: Auxiliary encoder
1: Motor
Z phase source of half-closed loop homing
0: Motor
1: Auxiliary encoder